Filter Results By:

Products

Applications

Manufacturers

Showing results: 31 - 45 of 204 items found.

  • Dual Bus 64-Channel 2A PCI Fault Insertion Switch

    50-190-102 - Pickering Interfaces Ltd.

    This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.

  • Dual Bus 75-Channel 2A PCI Fault Insertion Switch

    50-190-002 - Pickering Interfaces Ltd.

    This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.

  • Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel

    50-201-004 - Pickering Interfaces Ltd.

    This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.

  • Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel

    50-201-008 - Pickering Interfaces Ltd.

    This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.

  • PXI 11-Channel 2A Fault Insert Switch

    40-202-101 - Pickering Interfaces Ltd.

    This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test

  • DFB Laser Source Module

    LaserPXIe 1200 Series - Quantifi Photonics Inc.

    The LaserPXIe 1200 Series is a highly customizable DFB laser source available in a wide range of wavelengths and powers.

  • PXI Based Multifunction Measurement and ICT Instrument

    PXI-501 - Konrad Technologies GmbH

    The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.

  • PXIe Source/Measure Unit, 15 MSa/s, 1 PA, 60 V, 3.5 A DC/10.5 A Pulse

    M9602A - Keysight Technologies

    The Keysight M9602A is a PXIe SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.

  • PXIe High-Speed Source/Measure Unit, 13 V, ± 1 A or 6 V, ± 3 A, 18 W

    M9111A - Keysight Technologies

    The M9111A is a 1-slot, 2-quadrant PXIe module that provides stable, glitch-free sourcing and sinking, and high accuracy measurements. It offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. With industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading, the M9111A SMU speeds test time. The high-speed M9111A can change its output voltage, stabilize that voltage, and accurately measure current from Amps down to micro-Amps all in less than 1 ms so that you can move on to the next test as quickly as possible.

  • PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit

    783761-01 - NI

    PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.

  • PXIe-4139, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit

    782856-02 - NI

    PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 20 W of DC power. This module features analog-to-digital … converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.

  • PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit

    782856-03 - NI

    PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.

  • PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit

    783762-01 - NI

    PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4135 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.

  • PXIe-4135, PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit

    783762-02 - NI

    PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4135 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.

  • PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit

    783761-02 - NI

    PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers

Get Help